An AppDaemon app for Home Assistant OS. It allows electric heating (resistive heaters on two Shelly Plug M Gen3) whenever one kWh of useful heat is cheaper from electricity than from the gas boiler. Prices come from ANWB Energie's dynamic contract: hourly electricity, daily gas, both on EnergyZero market prices.

This directory has nothing to do with the ROS 2 packages in this repository. It uses neither colcon nor ROS. It only shares the repository's pre-commit hooks.

How it works

  • Operating model. The app switches the plugs, not the heaters. Plug ON means electric heating is allowed because it is cheaper; plug OFF means gas heats. A person switches each heater itself on or off, so "plug ON at 0 W" is normal and is reported as heater_active: false, never as a fault. There is no room-temperature control.
  • Every 5 minutes (hh:00, hh:05, …, aligned to the clock) the app compares the cost of one kWh of heat from each source and decides ON, OFF, or HOLD:
    electric heat = market price excl. VAT per kWh                      / heater efficiency (1.0)
    gas heat      = (market + ANWB fee + energy tax) per m³ / 9.769 kWh/m³ / boiler efficiency (0.90)
    
    It switches ON when electric heat is at least 2 ct/kWh cheaper, OFF when the advantage drops below 0.5 ct/kWh, and keeps each state for at least 15 minutes. Every gas tariff component is entered incl. 21% VAT.
  • Electricity at market price. The house produces a yearly solar surplus (about 2000 kWh in 2026), so a kWh used for heating costs what it would otherwise earn as feed-in: the market price excl. VAT, not the consumer price. ANWB fee and energy tax are left out of the decision on purpose. Without a yearly surplus this rule runs the heaters far more than is economical. The consumer price per kWh of heat is still published (sensor.heating_optimizer_elec_consumer_heat_price) and shown in the dashboard graph.
  • Fixed charges (standing charge, grid fees, energy tax credit) are excluded on purpose: they do not change with consumption, so they do not affect which source is cheaper for the next kWh. The energy tax used is the first-tier rate, which applies to normal household usage.
  • Gas day. The dynamic gas price changes at 06:00, not at midnight.
  • Failsafe. If the current price is unknown, the plugs go OFF: gas is the safe default.
  • Disable. Switching input_boolean.heating_optimizer_enabled off turns both plugs off once. After that the app stays hands-off, so you can switch the plugs by hand in HA.
  • Thermostat interaction. Savings come from the gas thermostat firing less while the electric heaters warm the room. Thermostat setpoint and location matter. Controlling the thermostat is out of scope.

⚠️ 3000 W heaters on a 13 A plug

The heaters are rated 3000 W at 230 V, which is exactly the Shelly Plug M Gen3's limit (13 A / 3000 W resistive). A resistive heater's power rises with voltage squared: about 3130 W / 13.3 A at 235 V and 3270 W / 13.6 A at 240 V.

  • The software safety check trips on current above 13 A for at least 10 s, on plug temperature above 70 °C, and on power more than 15% above the voltage-corrected heater rating (wrong or faulty appliance). Power above 3000 W alone does not trip.
  • Consequence: with the 13 A limit, a heater on its 3000 W setting will trip whenever mains voltage is above about 230 V, which is most of the time in the Netherlands. Each trip switches the plug off and locks it out until the next full hour. Use the heater's lower setting (e.g. 2000 W), or decide deliberately to raise plug_max_current_a, knowing that the plug is then run above its rating.
  • The plug's built-in overheat protection may also cut power during long full-load runs. The app detects this through the plug's error flags, logs it, and locks the plug out until the next full hour.
  • No on-device power limit is configured on the plugs (deliberate choice). The software protection only works while Home Assistant and AppDaemon are running. When they are down, the plug's built-in overheat protection is the only hardware backstop.

Layout

appdaemon/apps/
├── heating_optimizer.yaml      # AppDaemon app config (fill in energyzero_config_entry)
├── heating_optimizer_main.py   # AppDaemon entry module → heating_optimizer.main_app.MainApp
├── heating_optimizer_demo.py   # AppDaemon entry module → heating_optimizer.demo_app.DemoApp
└── heating_optimizer/          # the package; everything except main_app/demo_app is pure Python
docs/ha_setup.md                # Home Assistant setup, step by step
ha/                             # helpers, dashboard and recorder YAML
scripts/deploy.sh               # rsync over SSH to the Pi
tests/                          # pytest, no HA or AppDaemon needed

Differences from the original plan:

  • The app config is heating_optimizer.yaml, not apps.yaml, so deploying never overwrites other apps' config. AppDaemon reads every *.yaml in the apps folder.
  • Thin top-level entry modules are used because AppDaemon loads apps by top-level module name.
  • prices/service.py and devices/safety.py were added to keep the price logic and the safety rules pure and testable.

Development

cd HeatingOptimizer
pip install -r requirements-dev.txt
pytest
pre-commit run --files $(git ls-files HeatingOptimizer)   # from the repository root

The tests cover tariff math, gas/heat conversion, the price cache (gas day, 15-minute averaging, DST days), every decision branch, the house with a failing plug, the safety rules, clock alignment across DST, the decision log, and smoke tests of both AppDaemon apps against a stubbed AppDaemon API.

Deploy

cp scripts/deploy.env.example scripts/deploy.env   # set HA_USER
scripts/deploy.sh --dry-run                         # preview
scripts/deploy.sh                                   # copy and restart AppDaemon

heating_optimizer.yaml is only copied when it does not exist on the Pi yet. Use --config to overwrite it deliberately. See docs/ha_setup.md for the one-time Home Assistant setup.

First run

  1. Deploy, then press Demo 1. With energyzero_config_entry still TODO(user), it lists the EnergyZero entities and the config entry ID. Fill that in on the Pi and restart AppDaemon.
  2. Check the energy tax figures against the official Belastingdienst table. The 2026 values in the config (€0.11085/kWh, €0.72680/m³ incl. VAT) came from secondary sources.
  3. Run the demos. Each runs about 30 s, posts a notification with PASS/FAIL, and restores the plugs afterwards. Stop demo aborts and restores immediately. A demo pauses the main loop while it runs.
    • Demo 1 – electricity: today's price curve, cheapest/most expensive hours, consumer price breakdown, data source and age, call latency.
    • Demo 2 – gas: price per m³, per kWh fuel and per kWh heat, gas day, break-even electricity price.
    • Demo 3 – Shelly plugs: identity check (MAC via RPC, resolved IP and how), switch on, read every 3 s, switch off, restore. Switch the heaters on by hand first if you want the power check; otherwise it reports SKIPPED.
    • Demo 4 – house: all plugs on together with aggregated power, off, restore, then a simulated failure of one plug to show how it is reported (the other plug is switched for real and restored).
  4. Turn on input_boolean.heating_optimizer_enabled. From then on the app switches the plugs. Watch it for a couple of hours and check decisions.csv. Ticks should be within 2 s of each 5-minute mark, with a HOUR_CHANGE price lookup every hour.

Logs and diagnostics

On the Pi, under /addon_configs/a0d7b954_appdaemon/logs/heating_optimizer/:

  • decisions.jsonl and decisions.csv: one record per tick (including HOLD), with every price component, the margins, timers, and per-plug before/after/verified/power. Both rotate at 5 MB, 10 backups.
  • heating_optimizer.log: the application log (also in the AppDaemon log).
  • switch_on_counts.json: the switch-on counter per plug, keyed by MAC. Delete it to reset the counters.

Sensors in HA: sensor.heating_optimizer_status, _elec_heat_price (market based, the decision basis), _elec_consumer_heat_price (display only), _gas_heat_price, _price_delta, _elec_market_price (the raw EnergyZero electricity price excl. VAT; incl. VAT as attribute), _last_decision, _health (OK / DEGRADED / ERROR with the failing checks as attributes), and _demo_output. Per plug, sensor.heating_optimizer_<name>_switch_on_count counts every off → on of its switch, whether the app, a demo or a person switched it, and survives restarts. Switch-ons while AppDaemon is not running are not counted. ON/OFF changes also go to the HA logbook.

Health turns DEGRADED after tariffs_valid_until (2026-12-31) as a reminder to update the energy tax and the ANWB fees. Both change on 1 January.

Raspberry Pi notes

  • SD-card wear: the decision log adds about 288 small lines a day, which is fine. Use level: DEBUG only for diagnosis sessions. All log files rotate. Booting the Pi from a USB SSD is recommended.
  • Recorder: merge ha/recorder_exclude.yaml, so the per-tick status, health and demo sensors do not grow the SQLite database.
  • Clock: HA OS syncs time over NTP. The status sensor reports each tick's drift, and the self-test logs the UTC offset at startup.