Skip to content

State of heating is "idle" when physical controller is definitely on #663

Open

Description

@alexhorner
Image Image Image

When the physical controller is on (the heating channel light is on) the state of the thermostat often shows idle.

Activity

  1. asantaga commented on Jul 16, 2026

    @asantaga
    Owner

    Can you explain the issue a little more?

  2. alexhorner commented on Jul 16, 2026

    @alexhorner
    Author

    I'm not too sure how to explain this any better. All of the periods in the graph above where it is not orange, the state of the controller shows "idle", however it should be fully filled in as orange because the heating channel is actually on.

  3. asantaga commented on Jul 17, 2026

    @asantaga
    Owner

    Got it, alas I dont have any previous data to investigate (ie the heating is off).. and my historical data got trashed..
    I need to look at the code and work out where we get the idle from (hvac_action)..

    this may take until the heating comes on to diagnose....

  4. andyblac commented on Sep 28, 2026

    @andyblac
    Collaborator

    are you using V2 hub with opentherm connection?, if so it's a known issue, I'm on fixing atm....

  5. alexhorner commented on Sep 28, 2026

    @alexhorner
    Author

    are you using V2 hub with opentherm connection?, if so it's a known issue, I'm on fixing atm....

    No, this is a v1 hub in non-OpenTherm mode

  6. andyblac commented on Oct 3, 2026

    @andyblac
    Collaborator

    Thanks for confirming this is a V1 hub without OpenTherm. This looks similar to the OpenTherm issue, but it may have a different cause.

    The climate entity's heating/idle state is based on the individual room's ControlOutputState, while the light on the physical controller represents the heating channel relay. The channel can remain on because another room is requesting heat even when this particular room is idle.

    If this still happens with 4.0.0 RC1, could you confirm whether the room shown in the graph is actively requesting heat during one of the gaps? If possible, please also provide diagnostics captured while the controller light is on but the climate entity reports idle. This will let us compare the room demand with the heating-channel state and determine whether the hub is reporting inconsistent data.

  7. alexhorner commented on Oct 21, 2026

    @alexhorner
    Author

    @andyblac As we go into the winter season I will keep an eye on this on version 4.0.1 and update