You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
This repository was archived by the owner on Jun 5, 2019. It is now read-only.
Repository navigation
This repository was archived by the owner on Jun 5, 2019. It is now read-only.
The automated build calls build_solution with the following args for the MDK build: MDK 5.05 MCBSTM32F400
For GCC it uses an additional parameter to specify the project to build (relative to the solution folder): GCC 4.9.3 MCBSTM32F400 TinyClr_nonet\Tinyclr_nonet.proj
and again with: GCC 4.9.3 MCBSTM32F400 TinyClr_nonet\Tinyclr_nonet.proj
to validate the known GCC builds complete (which they don't , which is why the build status indicates partial success)
The additional and optional 4th parameter allows targeting a specific MSBuild project, if the extra parameter is not present then MSBuild will use the project file in the solution directory. If more then one exists it returns an error indicating that there is more than one and you need to specify which one you want.
@smaillet-ms yes, the current version does not have that and it fails to build a solution based with GCC. That's why I've raised this question. I'm on the dev branch.
I can only make it work with that 3rd parameter, otherwise it fails complaining with an invalid argument
Compiler: GCC 5.4.1
setting vars for GCC compiler GCC5.4.1
I think the better fix is in setenv_base:
in this area:
rem use a default for GCC
IF "%ARG3%"=="" (
SET "ARG3=%SystemDrive%\gnu\gcc"
IF NOT EXIST "%ARG3%" set "ARG3=%ProgramFiles(x86)%\GNU Tools ARM Embedded\4.9 2015q1"
)
IF NOT EXIST "%ARG3%" GOTO :BAD_GCC_ARG
Instead of immediately trying the legacy defaults, it can test for an Environment var that can be set once for the system to indicate the tool location.
Having multiple optional params on a CMD script makes things complicated. The tool path is generally not needed for MDK builds.
Question: can't be problematic relying on an environment var on a build machine that you might not have enough control to add that environment var? Shouldn't paths such as this be in a config file (exclusive on NETMF) that is read/parsed when the build process launches?
@josesimoes ENV vars are already used in the build servers to provide tool locations (among other things) At present for GCC, the build server and scripts rely on the default install paths from the tool installers, so no additional path is required. ANY change to the input arguments of build_solution (or build_sdk) necessitates changes in the automated build process.
Ideally none of these horrific setenvxxx scripts would be needed, BuildEnv.props was the start of that but various other aspects of 4.4 ended up taking a higher priority and I never got back to fully eliminating the environment scripts.
@smaillet-ms I think @cw2 suggestion above would solve this without braking anything and not requiring adding any environment vars.
And adding an hint for the correct usage would be helpful to people using GCC.
I've submitted PR #522 adding an explanation and examples and PR #523 for the script. Feel free to change that to something more meaningful or a better explanation.
Activity
smaillet-ms commentedon Oct 25, 2016
No idea - what branch are you based off of? The current dev branch version of build_solution doesn't have that.
The automated build calls build_solution with the following args for the MDK build:
MDK 5.05 MCBSTM32F400For GCC it uses an additional parameter to specify the project to build (relative to the solution folder):
GCC 4.9.3 MCBSTM32F400 TinyClr_nonet\Tinyclr_nonet.projand again with:
GCC 4.9.3 MCBSTM32F400 TinyClr_nonet\Tinyclr_nonet.projto validate the known GCC builds complete (which they don't , which is why the build status indicates partial success)
The additional and optional 4th parameter allows targeting a specific MSBuild project, if the extra parameter is not present then MSBuild will use the project file in the solution directory. If more then one exists it returns an error indicating that there is more than one and you need to specify which one you want.
josesimoes commentedon Oct 25, 2016
@smaillet-ms yes, the current version does not have that and it fails to build a solution based with GCC. That's why I've raised this question. I'm on the dev branch.
I can only make it work with that 3rd parameter, otherwise it fails complaining with an invalid argument
Compiler: GCC 5.4.1
setting vars for GCC compiler GCC5.4.1
Error - Invalid argument (C:\Program Files (x86)\GNU Tools ARM Embedded\4.9 2015q1). Usage: setenv_GCC.cmd GCC_VERSION GCC_TOOL_PATH
Example: setenv_gcc.cmd 4.2.1 c:\tools\gcc
A correct call has to be something like:
build_solution gcc 5.4.1 E:\GNU_Tools_ARM_Embedded\5_4_2016q2 STM32F4DISCOVERY
smaillet-ms commentedon Oct 25, 2016
I think the better fix is in setenv_base:
in this area:
Instead of immediately trying the legacy defaults, it can test for an Environment var that can be set once for the system to indicate the tool location.
Having multiple optional params on a CMD script makes things complicated. The tool path is generally not needed for MDK builds.
josesimoes commentedon Oct 25, 2016
Got you.
Question: can't be problematic relying on an environment var on a build machine that you might not have enough control to add that environment var? Shouldn't paths such as this be in a config file (exclusive on NETMF) that is read/parsed when the build process launches?
cw2 commentedon Oct 25, 2016
@josesimoes You can try tweaking the batch parameters with quoted strings (
%~to dequote, already used for the last msbuild parameter%~4):which would allow you to pass GCC version and path
You can use
^escape character for embedded quotes : )smaillet-ms commentedon Oct 25, 2016
@josesimoes ENV vars are already used in the build servers to provide tool locations (among other things) At present for GCC, the build server and scripts rely on the default install paths from the tool installers, so no additional path is required. ANY change to the input arguments of build_solution (or build_sdk) necessitates changes in the automated build process.
Ideally none of these horrific setenvxxx scripts would be needed, BuildEnv.props was the start of that but various other aspects of 4.4 ended up taking a higher priority and I never got back to fully eliminating the environment scripts.
Update script to dequote parameter
josesimoes commentedon Oct 26, 2016
@smaillet-ms I think @cw2 suggestion above would solve this without braking anything and not requiring adding any environment vars.
And adding an hint for the correct usage would be helpful to people using GCC.