Hi,
I would like to understand why the scores obtain using spliceai script and in https://spliceailookup.broadinstitute.org/ are different from the ones provided in the file spliceai_scores.raw.snv.hg38.vcf.gz,downloaded from Illumina basespace,and required to run VEP spliceai plugin.
Thank you.

Activity

  1. bw2 commented on Feb 15, 2024

    @bw2

    The difference is often because the precomputed scores were generated by running SpliceAI with a max distance of 50bp, while https://spliceailookup.broadinstitute.org/ has a default of 500bp.
    image. You can check if changing this to 50bp on the website resolves the difference.

    Another less frequent reason is that the precomputed tables are based on Gencode v24, while https://spliceailookup.broadinstitute.org/ now uses Gencode v44. To check if Gencode transcript definitions changed for your gene of interest you could open older and newer Gencode versions in IGV using the File > Load from Server.. menu.

  2. jml96 commented on Feb 15, 2024

    @jml96
    Author

    Thank you for your reply.
    I will check this.

  3. jml96 commented on Feb 16, 2024

    @jml96
    Author

    I have changed the maximum distance and now the spliceAI scores are consistent.
    Thank you for the help.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions