feat: ABC measurement log – measuring points, zones, verification, weather #930

Open

Description

@ChrArlt

Follow-up from the review comment on #791.

Problem / use case

The Gasmessprotokoll is built for CO in Wohnungen (Haus / Stockwerk / Wohnung, value, time). An ABC-Einsatz needs more, and the record must be kept for at least 40 years (HLFS Hessen, FwDV 500).

Proposed solution

  • measuring point with address or UTM, and zone (Gefahrenbereich ≥ 50 m outdoors or 5 m around the door indoors, Übergangsbereich ≥ 15 m; ABC-Konzept Bayern 1.2/1.3)
  • measuring order no., protective equipment, odour, soot/deposits, running number per point, device/sensor, method (Messzug NRW, Anlage 8a)
  • fluctuating values as a range
  • verification status unconfirmed / confirmed / outlier (two independent methods, ≥ 2 tube readings); outliers are marked, never deleted
  • weather and wind with timestamp, for the Fachberater ABC's dispersion forecast
  • the complete log in the PDF Bericht

Related: #429 (Dekon-Platz).

Sources: HLFS Hessen F-III ABC-Gefahrstoffe (2022); Staatliche Feuerwehrschulen Bayern, ABC-Konzept Bayern – Dekontamination (2022); IdF NRW, ABC-Schutzkonzept Messzug (2011).

Activity

  1. ChrArlt commented on Nov 8, 2026

    @ChrArlt
    CollaboratorAuthor

    Addition from Siegrist's Gastec Prüfröhrchen page (read 2026-11-08): the log cannot assume that every sample is air.

    • Sample medium per measurement (air, water, wipe, soil). Gastec sells direct-reading tubes for 10 substances in water, and its CBRNE-Koffer includes wipe, soil and water tests. The water tubes need a pH correction, so the log should have room for that note.
    • Qualitative screening results by substance class. The CBRNE-Koffer is a rapid test set for chemical warfare agents (nerve, blood and blister agents), toxic industrial chemicals, riot control agents, explosives and drugs, plus general protein detection (BioCheck). These results are detected / not detected for a class, not a value with a unit.
  2. ChrArlt commented on Nov 8, 2026

    @ChrArlt
    CollaboratorAuthor

    Two additions from the Gastec Gesamtliste:

    • Sampling aid per measurement. Readings can be taken through extension hoses (5, 10 or 30 m), a sampling lance, a probe for hot gases or a probe for fumigated containers. The sample point can therefore differ from where the crew stands, and the log should record how the sample was taken.
    • Units for liquid samples. Solution Tubes read in mg/l or ppm, so the unit must follow the sample medium proposed in my earlier comment.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    enhancementNew feature or request

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions