Atemschutz: an acknowledged alarm looks exactly like an unacknowledged one #654
ALARM QUITTIEREN in the workspace header silences every Trupp. Once pressed, nothing on screen shows that the alarm has been acknowledged:
IsAlarmAcknowledged is not bound in any .axaml; the header binds only the command (IncidentWorkspaceView.axaml:305-306).
CanAcknowledgeAlarm => IsAnyAlarm (ScbaViewModel.cs:671-681), so the button stays enabled and looks exactly as before.
A second Atemschutzüberwacher walking up to the ELW cannot tell whether a red, silent banner means "acknowledged" or "audio broken". Pressing again does nothing visible. Acknowledging a safety alarm has to be a visible state, not a hidden flag.
What already works: a Trupp that goes into alarm after the acknowledgement re-arms it (UpdateAlarm, :690-695).
Expected
After acknowledgement, the button is disabled and the banner says so ("QUITTIERT", or a distinct style class), until a new Trupp trips the alarm.
Per-Trupp acknowledgement is out of scope here; this issue only makes the existing global state visible.
Notes
Tests: acknowledge, assert CanAcknowledgeAlarm is false and the banner shows the acknowledged state; then trip a second Trupp, assert the alarm re-arms and the button is live again (pin the existing behaviour).
This touches the UI, so the PR needs a before/after screenshot pair.
Activity
feat(atemschutz): colour the whole row and card of an alarming Trupp (#…