Esc or ABBRECHEN discards a typed CO reading and typed Einsatzdaten without asking #652
Two editors throw away typed input on Esc or ABBRECHEN without asking:
CO-Messprotokoll. The reading editor's ABBRECHEN drops the buffer (CoMessprotokollViewModel.cs:1406-1413, CloseEditor → Editor = null), and Esc is bound to the same command (CoMessprotokollView.axaml:259, b:Overlay.CancelCommand="{Binding CloseEditorCommand}"). Every removal in this view asks first; losing a typed ppm value does not. A reading that has not been recorded is a gap in the Messreihe.
Einsatzdaten dialog.Cancel() just raises Closed (IncidentDataDialogViewModel.cs:91), and Esc maps to it (IncidentDataDialogView.axaml:13). Typed Stichwort, Einsatznummer and address are discarded. Lower risk — four fields — but the same pattern.
Expected
If the buffer differs from what is stored, Esc and ABBRECHEN ask first ("Änderungen verwerfen?"), with focus on ABBRECHEN as the destructive-confirm rule from epic: keyboard-only operation (tracking) #545 requires. If nothing changed, they close straight away, so the keyboard flow stays fast.
CO: the editor already knows what changed (HasStatusChange, HasCoValueChange, HasDetailChange, HasLabelChange); reuse the in-view confirm the building removal uses.
Einsatzdaten: compare the fields to the session values and raise a ConfirmDialogViewModel.
Notes
Tests: type a value, cancel, assert the editor is still open and the confirm is showing; cancel with no change, assert it closes.
Check KeystrokeBudgetTests still pass — the unchanged path must not gain a keystroke.
This touches the UI, so the PR needs a before/after screenshot pair.
Activity
feat: ask before Esc or ABBRECHEN discards a typed CO reading or Eins…